We started selling Delta products in 1979. Since then we have done about 25 AM Stereo installations at stations around the country for Delta. Here is the Delta booth at the 2001 National Association of Broadcasters Convention in Las Vegas. Left to right are Joe Novak of Delta, Mark Persons, and Bill Fox of Delta. |
New Delta DTCA Digital Antenna
Ammeter
FEATURES
100:1 Current Range
3-1/2 Digit Display
2% Accuracy Autoranging
Modulation Independent
Wide Frequency and Temperature Ranges
Dual 2.15 VDC/10 VDC Full Scale
with Remote Outputs
The Model DTCA Digital RF Ammeter provides AM broadcasters and other high power RF operators with an accurate,
reliable and high resolution digital instrument for measuring RF current.
The 100:1 dynamic operating range enables RF current measurement over a 10,000:1 power range and allows the broadcaster
to use a single instrument for day, night, pre-sunrise and post-sunset operating modes. The ammeter system uses the Model
TCT toroidal current transformer to provide a sample voltage proportional to the RF current. The ammeter converts this RF
voltage to a DC voltage which is applied to a 3-1/2 digit display. The reflective liquid-crystal display with 0.7 inch character
height provides a high resolution and easily readable RF current magnitude indication. Over the AM broadcast band, the
DTCA provides an accuracy of better than 2% with a resolution better than 1/100 of the RF current. The DTCA indicates the
average RMS current independent of amplitude or phase modulation. The dual remote outputs of 2.15 VDC full scale and 10.0
VDC full scale easily interface with existing remote monitoring equipment.
The DTCA circuit design is inherently wide band to extend RF current measurement capabilities for LF applications at
frequencies as low as 20 kHz and for HF applications at frequencies up to 5 MHz. The DTCA circuit is temperature
compensated to enable rated accuracy performance over a -40°C to +50°C temperature range.
SPECIFICATIONS
Frequency Range: 0.5 to 2 MHz at rated 2% accuracy, 20 kHz to 5 MHz with 5% accuracy
Operating Range: 100:1
Standard RF Current Ranges:
DTCA-10: 0.1 to 10 A
DTCA-20: 0.2 to 20 A
DTCA-40: 0.4 to 40 A
DTCA-80: 0.8 to 80 A
DTCA-160: 1.6 to 160 A
Indicating Instrument:
3 1/2 digit/2000 count reflective LCD display with 0.7 inch (17.8 mm) character height
Accuracy: Better than 2% of reading. Accuracy may be reduced if RF currents induced by other
stations are 5% or greater than the current to be measured.
Resolution: One part in 100 minimum, one part in 1200 maximum
Remote Outputs:
1) 2.15 VDC full scale, 16K source compatible with Delta Model TCA-IBA Buffer amplifier, output linear with RF
current
2) 10.0 VDC full scale, 16K source, output linear with RF current
Power Requirement: 120/240 VAC primary/18 VAC @ 200mA secondary power module (supplied) or 18
to 28 VDC, 80 mA power supply (TCA-PS2 or equivalent)
Range Selection: Automatic
Current Transformer: Delta Model TCT, TCT-HV or TCT-XHV for AM broadcast band (500 kHz to 2
MHz); Suitable transformer required for lower/higher frequencies
Interconnecting Cables: Standard six foot, 50 Ohm coaxial cable supplied to connect transformer unit to
detector/display unit. Longer cable length and double shielded coaxial cable are
optionally available. Conductor Voltage to Ground (RMS Equivalent of Peak Modulation Voltage):
DTCA-N Series: 10 kVRMS
DTCA-N-HV Series: 20 kVRMS
DTCA-N-XHV Series: 42.4 kVRMS
Temperature Range: -40°C (-40°F) to +50°C (+122°F)
Modulation Characteristics: Indicates average RMS current with minimum modulation effect. Will indicate carrier
shift.
TCA RF Ammeter Upgrade
Users of Delta's Model TCA RF Ammeter System may easily upgrade to the Model DTCA Digital RF Ammeter System. The
digital ammeter is interchangeable with the TCA ammeter for both RF input and remote DC output. Please contact the factory
to arrange return of your TCT unit for calibration with the DTCA Digital RF Ammeter.
Price: $2995.00 to $5950.00 depending on model.